Supported projectors and meters

ProjectorCal does not need a model-specific database. It measures, suggests a change, measures again and learns how many percent one menu step moves your projector. What a profile adds is the menu layout that cannot be learned: how many gamma points there are, and which meter timing to use for the automatic run.

Verified means full calibration runs on real hardware. Everything else is expected to work and is set up from the same assumptions. Please report your model (see Help us verify your model).

Projectors

Model Status Gamma points (Control Point) Notes
Vidda C3S ✅ verified (7 full runs) 20 × 5 % Case study
Vidda C3 / C3 Pro / C3 Ultra expected to work 20 × 5 % (assumed) Same VIDAA Expert menu family
Hisense / Vidda C2, C2 Pro, C2 Ultra, C2 Max expected to work 20 × 5 % (assumed) Check the point count in your menu
Hisense / Vidda C1, C1S expected to work check  
Hisense PX1 / PX2 / PX3 (Pro) laser UST expected to work check White Balance + Gamma Calibration in the Expert menu
Hisense Laser TV (L5, L9 …) white balance + CMS none (start with this) 2-point and multi-point white balance
Any other projector or TV white balance + CMS 20, 10 or none Needs Gain/Offset (or RGB high/low) white balance

The models above run Hisense’s VIDAA system and share the same style of Expert picture menu: Color Temperature → White Balance (Gain / Offset R G B), Gamma → Adjust → Control Point (Gain), Color Tuner / CMS (Hue, Saturation, Brightness of 6–7 colors). Menu names differ slightly between models and firmware versions.

Choosing the gamma layout

Open Gamma → Adjust (or Gamma Calibration) in your projector menu and count the Control Points.

Not sure? Pick the closest layout and use Gamma by points → point probe: change one point by a few steps, do a check pass, and the program shows at which gray step that point’s effect peaks.

What else differs between models (and how the program copes)

Quantity On the C3S On other models
Gain: effect per step learned in the first run with a Gain change the same
Offset: effect per step coarse, ≈ 5 % at white, 25 % at 20 % gray learned from a run with an Offset change
Gamma point: % per step ≈ 2.3 % of its step’s luminance learned from the first gamma round
CMS Bright / Saturation ≈ 10–12 % / ≈ 2 % per step learned from the first CMS change

Until a step size is learned, the program limits the first change (e.g. at most 2 steps of Gain) so an unknown projector is never pushed far in the wrong direction.

Meters (colorimeters and spectrometers)

ProjectorCal talks to the meter through ArgyllCMS spotread, so any instrument ArgyllCMS supports can be used. Pick the model in Settings → Meter model: it decides which automatic video to play.

Meter Status Auto-run video Notes
Calibrite Display Plus HL ✅ verified standard Run Calibrite PROFILER once so third-party software can use it
i1Display Pro, i1Display Pro Plus, Calibrite ColorChecker Display Pro / Plus expected to work standard Same i1Display family; ≈ 1 s on white, up to ≈ 10 s on black
ColorMunki Display, i1Display Studio, Calibrite ColorChecker Display expected to work slow Same sensor, firmware-limited to slower readings
Datacolor SpyderX / X2 / Spyder (2024) / Spyder5 / Spyder4 expected to work slow Warm up 10–15 min; black calibration when asked. Spyder4/5: install calibration data once with ArgyllCMS oeminst
X-Rite i1Pro / i1Pro 2 / i1Pro 3, ColorMunki Photo / Design, i1Studio expected to work slow Spectrometers: accurate color, noisy below ≈ 1 nit — the darkest patches may be flagged. White-tile calibration at start
Klein K10-A expected to work standard Fast and very good in low light
DTP94, Huey, ColorHug / ColorHug2, Spyder2/3, JETI specbos / spectraval, HCFR should work slow Older/slower devices: gray tracking and gamma are fine, absolute color is less certain

The slow videos show every patch twice as long (SDR ≈ 27 min instead of 14, HDR10 ≈ 13 min instead of 6.5). If a meter is even slower than that, the program does not guess: the patches it could not read are flagged and left out of the analysis.

Accuracy on laser projectors

Laser light has very narrow spectral peaks. A colorimeter’s factory calibration was made for other displays, so its absolute white point and saturated colors can be off by a few hundred kelvin / a few ΔE on an RGB-laser projector. What stays reliable: gray-scale tracking, gamma, and every change between runs — which is what calibration is about. To get absolute accuracy as well:

Help us verify your model

Calibrated a model that is not marked as verified? Open an issue titled **“Verified: + "** with:

  1. projector model and firmware version, meter model, ArgyllCMS version;
  2. the number of gamma Control Points in your menu and, if you ran it, the point-probe result;
  3. the exported JSON of your runs, or at least the run table from the Full check screen (γ, gray ΔE, color ΔE).

That is enough to mark the model as verified and to add its measured step sizes as starting values.